Powertron Logo


Ozone generator information guide for applications and use



Ozone (O3) Properties

Molecular Formula

: Oł

Molecular Weight

: 48

Color

: light blue / colourless

Solubility in Water (@ O°C)

: 0.64

Density

: 2.144 g/l

Electrochemical Potential

: 2.07 Volts

The Smell of O3

: O3 at low concentrations ( 0.01 - 0.04 PPM ) leaves a fresh and pleasant smell to a room.
: Higher concentrations exhibit an “electrical” odor. This is typically smelled after strong lighting or a
: rainstorm.

Half Life

: As soon as ozone is formed, it starts to decay to oxygen. The half life is 2˝ minutes to Hours.
: in most applications, depending on the ambient conditions. In cool, sterile environments the
: half life can extend to Hours. Higher temperatures lead to shorter half life.
















Ozone Solubility

The solubility of O3 depends on the water temperature and the O3 concentration produced by the ozone generator (Units in mg/l or ppm)



Oł Gas
5°C
10°C
15°C
20°C

1.5%

11.09

9.75

8.40

6.43

2%

14.79

13.00

11.19

8.57

3%

22.18

19.50

16.79

12.86






Oxidation Reduction Potential and ozone generators

ORP is a term used frequently in the water treatment & food processing industry. ORP stands for Oxidation-Reduction Potential. So what is that? The best definition I can give is that “ORP is a measure of the cleanliness of the water & its ability to break down contaminants”. It has a range of -2,000 to + 2,000 and units are in “mV” (millivolts). Since ozone is an oxidizer, we are only concerned with positive ORP levels (above 0 mV).

O3 owes its excellent bactericidal, viricide, and sporicidal activities to its powerful oxidizing properties. O3 has an oxidation reduction potential of +2.07 volts as compared to HOCL (the active form of Chlorine in aqueous solution) which is +1.49 volts. It is reported to be 3000 times faster acting than chlorine. It retains this strong oxidizing capability in aqueous solution, a property crucial for water disinfection and sterilization, as well as in high humidity air applications.

ORP sensors work by measuring the dissolved oxygen. More contaminants in the water result in less dissolved oxygen because the organics are consuming the oxygen and therefore, the lower the ORP level. The higher the ORP level, the more ability the water has to destroy foreign contaminants such as microbes, or carbon based contaminants. Orp controllers can be used to control ozone generator output in water treatment applications


The chart below identifies ORP levels for various ozone generator applications:



ORP Level (mV)
Application

0-150

No practical use

150-250

Aquaculture

250-350

Cooling Towers

400-475

Swimming pools

450-600

Spa Baths

600

Water Disinfection *

800

Water Sterilization **

* Disinfection is destruction of specific pathogenic microorganisms

** Sterilization is the destruction of all microbial life





How does an ORP meter work?


An ORP meter measures very small voltages generated with a probe placed in ozonated water. The electrode is made of platinum or gold, which reversibly looses its electrons to the oxidizer. A voltage is generated which is compared to a silver (reference) electrode in a silver salt solution, similar to a pH probe. The more oxidizer available, the greater the voltage difference between the solutions.


O3 compared to other gaseous disinfectants


Gaseous disinfectants in common use are sulphur dioxide, formaldehyde, and in certain applications, hydrocyanic acid. It has been clearly demonstrated that ozone in equivalent concentrations exerts a much stronger bactericidal effect than any of the foregoing disinfectants. To obtain the same bactericidal effect concentration of 160 times the amount is required for sulphur dioxide, 37 times the amount for formaldehyde, and 1.7 times the amount for hydrocyanic acid gas.


Some specific compounds oxidized by Ozone:



O3 effects on Bacteria and Viruses:

Bacteria are microscopically small, single-cell creatures having a primitive structure. They take up foodstuffs and release metabolic products, and multiply by division. The bacteria body is sealed by a relatively solid-cell membrane. Their vital processes are controlled by a complex enzymatic system. Ozone interferes with the metabolism of bacterium-cells, most likely through inhibiting and blocking the operation of the enzymatic control system. A sufficient amount of ozone breaks through the cell membrane, and this leads to the destruction of the bacteria.

Viruses are small, independent particles, built of crystals and macromolecules, Unlike bacteria, they multiply only within the host cell. They transform protein of the host cell into proteins of their own. Ozone destroys viruses by diffusing through the protein coat into the nucleic acid core, resulting in damage of the viral RNA. At higher concentrations, ozone destroys the capsid, or exterior protein shell by oxidation so DNA (deoxyribonucleic acid) or RNA (ribonucleic acid) structures of the microorganism are affected. In fact, DNA and RNA breakdown products could be identified in this case.

O3 can be used to detoxify cyanide wastes (for example from gold and silver mining) by oxidizing cyanide to cyanate and eventually to carbon dioxide.


Ozone effects on bacterial aerosols

Aerosols were produced by spraying bacterial suspensions at 20 lb/sq. in pressure and concentrations of bacteria were in the range of 50-500 viable organisms per liter of air. The killing effect of ozone was determined by comparing the curves for decay with, and without, ozone. Ozone concentrations ranged from 2.0 PPM (parts per million) down to 0.023 PPM. Tests were performed on three organisms; Streptococcus salivarius, Streptococcus 'C' and Staphylococcus albus. The role of humidity in the action of ozone, particularly when the gas is at low concentration, was apparent. At humidities less than 45%, ozone, even in high concentrations, exerts no appreciable disinfecting action on bacteria. For humidities above 50%, however, ozone reduced the bacteria count. In fact, ozone as low as (0.025 PPM showed definite bactericidal action at 60 to 80% humidity.


Bacteria that have settled on surface

Bacteria on surfaces constitute a potential infection danger as a source of infection through redispersal in the air or contact with skin or clothes. Tests were made to determine whether ozone has any disinfecting action on deposited bacteria. Bacteria were sprayed on various surfaces: moist agar in Petri dishes; Whatman filter paper; sterile glass Petri dishes and wool cloth. These were placed in known conditions of humidity (range 60-85%), temperature and ozone concentration. After being exposed, the bacteria were counted and compared with surfaces having bacteria not exposed to ozone. Ozone in a concentration of 0.02 PPM in a moderately humid atmosphere exercises a very definite killing effect against bacteria on surfaces, but below this level it has little effect.

The kill depends on (a) the "depth" and type of surface; so moist agar, Whatman #1 filter paper and wool cloth are more favorable to survival than glass or #50 Whatman paper; (b) resistance to ozone of different types of bacteria: Staphylococcus albus resistance is greater than Streptococcus Salivarius, which in turn is greater than B.prodigiosus.


Discussion

Ozone, in concentrations up to 0.04 PPM in humid atmospheres exerts a disinfecting action on certain bacteria; streptococcus salivarius, Streptococcus 'C', Staphylococcus albus and B. prodigiosus. Tests on E. coli with up to 1 to 2 PPM in relatively dry air failed to destroy any organisms. This confirms ozone is a poor disinfectant at low humidities. However, at humidities above 60% tests confirmed pathogens can be destroyed by minute amounts of ozone. Increasing the moisture content of the environment favorably influences germicidal effect. This is brought about by swelling of microbes making them more susceptible to destruction.

The effect of ozone below a certain critical concentration value is small or zero. Above this level all pathogens are eventually destroyed. This effect is called all-or-none response and the critical level the "threshold value”.

There is a two-step process of inactivation or viruses. Period one lasts less than 10 seconds, during which time a kill rate of about 99% is achieved. Period two runs for several minutes to complete destruction. This phenomenon is independent of changes in ozone concentration between 0.07 and 2.5 mg/l.


Ozone Applications for Ozone generator use


Odour Control

Ozone is unmatched as a deodorizer. Ozone has a strong characteristic odor even at very low concentrations. Its effect on the olfactory membrane makes it difficult or impossible to detect other odors when ozone is present. In low concentrations (0.01-0.02 PPM), ozone acts is a masking agent on most odors. Tests have demonstrated that room odors were undetectable even when ozone concentrations were less than 0.01 PPM.

Some very delicate odors are destroyed even at these low concentrations. However, to totally eliminate "heavy" odors higher concentrations of ozone are required to react with gases in the air and odors trapped in materials. Time to deodorize is determined by the quantity of the substance producing odor and the quantity of ozone available to react with it.

Ozone at a concentration of 0.1 PPM will destroy micro-organisms and eliminate most odors within 48 hours.

Odoriferous substances are susceptible to oxidation, but the addition or oxygen to a substance (oxidation) dues not always render it safe. For example, oxidation of allyl alcohol yields aldehyde acrolein, a very deadly gas. Safety considerations apply only to definite industrial odors and do not include animal wastes or putrefactive gases of animal or vegetable tissue. Putrefaction produces highly odorous substances such as amino, aromatic and fatty acids, indole, skatole, cresol. said also the alkaloid-like ptomaines, such as tetramethylene-diamine and pentamethylene-diamene, etc. The effect of ozone on these substances is that of combustion and the final products of the hydrocarbons being CO2 and water and those containing nitrogen, nitrogen pentoxide.

Where putrefaction occurs - the air from sewers, etc. - while highly odoriferous, contains but traces of these substances. The odors are easily and completely destroyed by ozone. Ozone has been used in San Francisco to deodorize a sewage pumping station when the pump screens had to be cleaned. A rat died in a wall of an office building and the odor penetrated several offices. The application of ozone completely destroyed the odor.

Single atoms of oxygen from the decomposition of ozone immediately oxidize odors. The lower the temperature and the larger the odor molecules, the weaker the oxidizing effect. Humidity lists no effect on this process, but does accelerate destruction of bacteria, viruses and fungi that may contribute to odor.


Sterilizing

Ozone at ambient temperatures is the only substance which can be used as a total sterilizing agent and a substitute for high temperature. Pyrogens, byproducts of microbial growth that are toxic to humans, are not eliminated after normal autoclaving or dry heat sterilization. Pyrogens adhere firmly to surfaces of containers and are removed only after heating at very high temperatures for extended periods of time. Because pyrogenic material is a lipopolysaccharide, the unsaturated double bonds are easily oxidized by ozone. Therefore, ozone has a distinct advantage over other depyrogenation methods.


Ozone use in Air Conditioning

Molds in ducts, filters and other parts of ventilating equipment, in basements and other damp places produce objectionable odors. In low concentrations ozone masks odors, giving a freshness to the air normally absent in recirculated air. Also with time and the right humidity conditions, ozone destroys bacteria and mold. Where possible, ozone should be introduced in sufficient quantity to mix with all the air when the building is unoccupied. With recirculation, this will build up a concentration sufficient not only to deodorize the air but thoroughly disinfect and sterilize the entire building and HVAC equipment. This will result in the reduction of molds, bacteria and decomposing organic material in the duct work and parts of the equipment that are inaccessible. This work should be completed and the ozone reduced to acceptable levels before the building is occupied again.

Effect of ozone on Escherichia coli and Staphylococcus aureus - W.J. Kowalski. Penn State University: Controlled levels of ozone are used in Europe in air conditioning systems to deodorize and freshen air in theaters, shopping malls, offices, etc. Demand for make-up air is reduced as the recycle system furnishes air of sufficient purity. Body odors, cigarette smoke mid various unpleasant smells are removed. These gases are mostly hydrocarbons, together with hydrogen sulfide and are rapidly destroyed by ozone.

Our body automatically controls respiration. When air contains even minute and practically imperceptible quantities of disagreeable odors we involuntarily shorten out breathing. Even though rate of respiration may increase under such conditions, the total volume of oxygen taken into our lungs is reduced. This results in a mild form of autointoxication as wastes increase in the blood, and we feel lethargic and tired. In 1919, the first ozone generator was installed in the air duct of the O'Fallon School (St. Louis). The effects were so positive that ozonators were installed in thirteen old schools and three new ones. Teachers and administrators noted an improvement in the health of the children and a reduction in the number of colds.

The St. Louis Hygiene Department kept a record or all absences on account of illness, the nature of the disease and time lost. Two tests were conducted, one in the morning without ozone and one in the afternoon withozone. Physicians from the Hygiene Department exposed agar dishes and delivered them to the City Bacteriologist for incubation and count. The afternoon test with ozone averaged half the bacteria count of the morning test when no ozone was used. Another test was conducted with 65% recirculated air. Recirculated air with ozone gave 36% less bacteria than 100% fresh air without ozone. Odors were entirely absent in the recirculated air test.


Health and Medicine

"Exposure to ozone reduces influenza diesease severity and alters distribution of influenza viral antigens in murine lungs."

This study was undertaken to assess the effects of exposure to ozone on the course of influenza virus infection. Mice were exposed to ozone or filtered air, or both, with aerosolized infection by influenza virus. It was found that animals exposed to ozone during infection showed a reduced severity of disease measured by decreased mortality and delayed time of death.

Ammonia, and to some degree hydrogen sulfide, affect pig performance directly (by altering metabolic reactions) and indirectly (by influencing pig health). Atmospheric ammonia was particularly damaging to young pigs infected with Ascaris suum. Ozone reduces harmful ammonia and hydrogen sulfide. Ozone converts ammonia (NH3) to harmless nitrogen and water vapor. Hydrogen sulfide (H2S) is broken down into water and sulphur dioxide, also a powerful disinfectant


Ozone Therapy

Ozone has been used successfully around the world for over 80 years to treat:

and over 150 more diseases. In some clinics around the world, ozone therapy is the first agent given to each and every patient that enters the clinic regardless of their ailments. German ambulances even carry ozone generators for emergency use. Ozone Therapy addresses the key issues in almost all disease conditions: oxygen delivery, circulation, and immune system function.


Types of Ozone therapy include:

Ozone Sauna: normal sauna application where ozone is introduced in controlled amounts


Auricular Insufflations: irrigate the ear canal with the ozone / oxygen mixture from a medical ozone generator


Vaginal Insufflation: a vaginal cannula is used to introduce the ozone gas to the patient


Body Suit: the O3 gas is infused into the body tight suit. suit is sealed at ankles and wrists


Bagging: method of isolating a body part by surrounding it with a bag (such as hand, arm, leg, foot, torso, pelvis, but NEVER head), and introducing ozone.


Major Autohemotherapy: This procedure is performed only by trained professionals, usually only in a clinic setting. Approximately 200cc of the patients blood is withdrawn into an evacuated bottle. The bottle is then hung upside down, and ozone gas (the same volume as the blood withdrawn) is infused into the bottle, usually at a concentration of 40ug/ml. The blood is then given back to the patient, much like a transfusion.

Major Autohemotherapy is the preferred method of many practitioners, and it is used in well over 150 diseases. In Germany, even the ambulances are equipped with ozone generators; if ozone is administered within 24 hours of a stroke, 95% of patients suffer no permanent paralysis.

Ozonated Olive Oil: Ozonated Olive Oil is used around the world for a variety of uses:

This appears to be the only way to stabilize ozone without adding artificial stabilizers, chemicals, or preservatives. Ozone is bubbled at very high concentrations, under a controlled environment for days until it slowly begins to solidify. This solid form of olive oil forms a Vaseline or salve like substance and will keep for many months on the shelf. If kept refrigerated, it maintains its full effectiveness almost indefinitely.

Some individuals even choose to ingest ozonated olive oil in order to obtain the system wide effects of using ozone medically.


Ozone use in Product Storage and refridgeration

Ozone has been used in food preservation since 1909. Storage places, warehouses & refrigerated lockers can be disinfected. High humidity in the environment favorably influences germicidal effect. Ozone decomposition is accelerated due to high moisture content, the walls of the storage room, the packaging materials, the absorption effect of the stored goods, and also the oxidation reactions taking place. The ozone generator must have sufficient capacity to maintain ozone at the required level. A strong air movement is required to assure optimum distribution of ozone. The storage space need not be air tight as long as the capacity of the ozone generator is sufficient to replenish the ozone lost through air exchange.

The prerequisite in the control of microorganisms is the maintenance of clean environment. The microbial population of the product and the storage environment determine the storage life of the product. When a food product is exposed to contamination during preparation, handling or storage, large numbers of microorganisms are introduced into the product. In food, micro-organism find a favorable habitat for growth and each new generation of bacteria means a doubling of the population. The result is a breakdown of the food product evidenced by objectionable physical appearance, taste and odor.

There is no compound that can be applied to a dirty surface to destroy all microorganisms. To demonstrate, a good sanitizer was applied liberally to a ditty wail in a food handling plant. This wall had a bacterial population of 28,000,000 organisms on a two-inch square. Five minutes after treatment the wall still had a bacteria count of 11,000,000. Although the contamination had been reduced, the wall was still heavily contaminated A food product entering this storage room had a relatively low surface bacteria count, but in 48 hours the product had a count of 150,000 in a two-inch square. Air examination showed an extremely high bacteria count. Even though multiplication of bacteria might be slowed by low temperature, the product was acquiring high count that would reduce its shelf-life after it left the storage room. If kept for a longer period in storage, its storage life would be considerably shorter than if stored in a room relatively free of contamination.


Fish Storage

Freshly caught fish can be stored longer if washed in water containing ozone. If it is packed in ice made from water containing ozone. Freshness can be extended.


Ozone control of surface microflora

In a refrigerated atmosphere with ozone, the growth of the surface microflora (pseudomonas families, spores, Salmonellae and staphylococci) is eliminated or retarded.

Forequarters of beef with relatively equal bacteria counts were tested, one in the ozone-treated refrigerator at a concentration of approximately 0.1 PPM of ozone and 60-deg F, and the other under similar conditions except for the lack of ozone. At the end of the test period, the ozone-treated beef had about the same count as at the start, but the untreated beef showed an increase of 600 percent.

Ozone used in beef storage is most efficient if the meat surface has around 60% moisture content.

Beef stored in a cooler under an ozone concentration of 0.04 PPM at 2-deg C, experiences 0.9 to 1.0 percent less shrinkage in three days and 17 percent less in 7 days. Trim loss is reduced by 2.6 to 5.5 percent. This is less shrinkage and trim loss than meat stored under identical conditions but without ozone usage.

The storage life of beef a refrigerated state can be increased by 30 to 40 percent if the beef is kept in an atmosphere of 7.7 to 15 PPM. and the microbial saturation of its surface is not greater than 1000 bacteria per square cm.


Ozone use in Aquaculture


Ozone generator use in Cooling Towers


Fire Restoration with Ozone


Soil Remediation with Ozone


Food Preservation with Ozone


Ozone generator Water Treatment:


References:

extracts taken from: - Warren Wood - www.ozonet.com - Oxygen healing therapies - www.oxygenhealingtherapies.com - The Analyst - www.digitalnaturopath.com - Sinuswars - www.sinuswars.com

Disclaimer:

"This area is for information only, and should not be considered as professional or medical advice. To make an informed decision we suggest you consult other sources of information. We accept no responsibility for information inaccuracy in this text. Please consult with you health practitioner before considering any therapy or therapy protocols."



Contact us



> Back to top